Regular maintenance of the Honda GX50 motor includes checking the oil level, changing the oil at recommended intervals, inspecting and cleaning the air filter, and ensuring the spark plug is in good condition. Refer to the Honda engine manual for specific service schedules and detailed instructions.
Yes, the FireGuard™ can be operated in cold conditions. However, it’s important to ensure that water inside the tank does not freeze, as this can damage the pump and hoses. In freezing weather, drain the system after use or store the unit in a warmer environment to prevent frost damage.
Yes, the FireGuard™ is compatible with other hoses that fit the ¾” outlet connection. Ensure any additional hoses meet appropriate fire safety and pressure ratings to maintain optimal performance and safety during operation.
After use, drain any remaining water from the tank and pump, clean the system thoroughly, and store the unit in a cool, dry area out of direct sunlight. Check hoses and fittings for signs of wear before long-term storage, and ensure the motor is protected from dust and moisture.
Yes, the pump can also be used for general water transfer, washdown, and tree watering applications. Always use clean water to prevent debris from entering the system and avoid damage to the pump components.
If the pump fails to deliver water, check that the suction hose is fully submerged and free of leaks or blockages. Confirm that the tank contains enough water and that all fittings are secure. If issues persist, refer to the user manual for troubleshooting or contact TTi for technical support.